晸准的特马网站

technical article

> 技术文章 > 常熟瑞特电器研发中心能耗监测系统的应用 Current page: 晸准的特马网站 > Technical Articles > Application of Changshu Ruite Electric R & D Center Energy Consumption Monitoring System

Application of Energy Consumption Monitoring System of Changshu Ruite Electric R & D Center

Contributed by Ankerui Electric Co., Ltd. 2019/12/23 8:46:30

0 Popularity: 3

  • Keywords: Energy consumption monitoring system ACREL-5000
  • Abstract: With the improvement of social living standards and the prosperity of the economy, people's demand for energy has gradually increased, resulting in an increasingly serious energy crisis. How to understand, analyze and control the school's energy consumption in real time has become an urgent problem to be solved. Traditional energy consumption intelligence is performed on a monthly / quarterly / yearly cycle. However, schools are daily and hourly, and energy consumption occurs daily and hourly. This article introduces the Changshu Ruite Electrical Appliance R & D Center project, which uses Ankerui intelligent power meters to collect various electrical parameters at the power distribution site. The system adopts the on-site networking method. After networking, it is implemented by the Acrel-5000 energy consumption monitoring system Monitoring and management of power consumption in each distribution circuit.

Ankerui Electric is an enterprise serving environmental protection assessment, environmental protection testing, environmental protection equipment submetering, environmental protection equipment electricity monitoring and other projects.

Abstract: With the improvement of social living standards and the prosperity of the economy, people's demand for energy has gradually increased, resulting in an increasingly serious energy crisis. How to understand, analyze and control the school's energy consumption in real time has become an urgent problem to be solved. Traditional energy consumption intelligence is performed on a monthly / quarterly / yearly cycle. However, schools are daily and hourly, and energy consumption occurs daily and hourly. This article introduces the Changshu Ruite Electrical Appliance R & D Center project, which uses Ankerui intelligent power meters to collect various electrical parameters at the power distribution site. The system adopts the on-site networking method. After networking, it is implemented by the Acrel-5000 energy consumption monitoring system Monitoring and management of power consumption in each distribution circuit.

Keywords: factory; office building; energy consumption monitoring system; ACREL-5000

1 Introduction

        With the deepening of energy conservation, the scientific management methods of energy utilization are becoming more diverse. The energy consumption management system can monitor the detailed use of various energy sources in the school in real time, find weaknesses in energy consumption for public buildings, promote the improvement of school management and reduce operating costs, and provide an intuitive and scientific basis for energy conservation and consumption reduction. As an efficient management tool and emerging management means, energy consumption management systems have been applied in large public buildings, hospitals and other fields. Changshu Ruite Electric R & D Center Acrel-5000 energy consumption management system reduces energy consumption and improves profit through energy collection and management.

2 Design basis

GBT23331-2009 "Energy Management System Requirements"

GB-50052-2009 "Code for Design of Power Supply and Distribution System"

♦ National and industry standards for energy consumption measurement devices

DL / T 645-1997 Multi-function Energy Meter Communication Protocol

DL / T 645-2007 Multifunctional Energy Meter Communication Protocol

CJ / T 188-2004 Technical Conditions for Data Transmission of Household Meters

3 Project Overview

        Changshu Ruite Electric R & D Center mainly monitors floor multi-function meters. A total of 94 PZ series meters manufactured by Ankerui are divided into 4 bus access systems.

4 System architecture

        According to the actual situation of the public construction site, the Acrel-Acrel-5000 energy analysis management system uses a shielded twisted pair to directly connect to the background energy gateway and then upload the data to the monitoring host through the TCP / IP network. The details are shown in the following figure:

        The system mainly uses a layered distributed computer network structure, as shown in the system structure diagram: station control management layer, network communication layer and field equipment layer. The meters in the entire building are distributed in the power distribution room and floors. All the meters are laid to the monitoring center through 485 shielded twisted-pair wires, and are collected and managed by the energy gateway to the system host.

5 System software modules

♦ Main interface of comprehensive energy consumption

        The main page displays the building's architectural picture, basic building information, the monthly electricity pie chart of the building, and various energy consumption. According to the selected building, load its building picture, you can choose the time to view the energy consumption of the building, select the building or the time to automatically refresh, the default is the day.

♦ Energy use of branches

        The system can count the energy usage of each branch road day by day, week by week, month by month, quarter by quarter, and year by year. The system can view the energy consumption trend of each branch, and can make inquiries based on the existing date or custom time, and can display the total energy consumption of the branch in a chart form.

♦ Itemized energy consumption statistics

        The system can perform energy consumption statistics and display according to items. Among them, the year-on-year analysis chart of daily energy consumption shows the energy consumption histograms of different sub-items for the day and yesterday (the blue bar represents today and the green bar represents yesterday); the energy pie chart shows the energy consumption of each sub-item in the past 31 days. The stacked graph shows the energy consumption trend of each sub-item in the past 31 days. The sub-item energy ranking chart shows the top 10 branches of the energy consumption value corresponding to the selected sub-item.

♦ Itemized energy consumption report

        The system can count daily, weekly, monthly, quarterly, and yearly energy consumption of each sub-item within a certain period of time. You can view the energy consumption trend of each branch in the sub-items, you can query based on the existing date or custom time, and the statistical data can be exported to Excel.

♦ Year-on-year analysis of energy consumption

       The system can analyze the energy consumption of each major energy-consuming equipment from the same period of last year and the value of the previous month on a year-on-year basis, check the energy-saving effect, perform energy-saving performance assessment, and revise energy-saving targets based on the analysis results. Statistics on the monthly energy consumption of each branch road in the current year and the same period last year;

♦ Energy data check

       The system can calculate the energy difference between each loop and the lower branch in a certain period of time. When it exceeds a certain percentage, it will be prominently displayed (red area) to ensure the integrity and accuracy of the measurement system.

Configuration options

       Configure the basic information of the building in accordance with the relevant technical specifications, such as: building functions, building area, air-conditioning area, building address, etc., where the building area and other information will be analyzed by energy consumption per unit area;

       Configure basic information such as the type, model, and manufacturer of the meter used in the project, and add the monitoring parameter information that the meter can provide. The configuration here affects energy consumption statistics, energy consumption statistics by period, and parameter query functions;

       Configure all measuring instruments used in the project, and save the address, transformation ratio, corresponding collector, code, name of the monitoring circuit and other information of the measuring instrument;

       The information such as the meter, proportion, and calculation method involved in configuring the energy consumption statistics of each item can be flexibly configured according to the project situation. The configuration information here will affect the functions in the energy consumption analysis modules of each category. ;

       Configure the energy consumption metering, calculation method, proportion and department energy consumption plan for each department. After completing this configuration, the department energy analysis function module will be enabled;

       Configure the meter, calculation method, and proportion corresponding to an energy-consuming area in the building. After completing this configuration, the regional energy analysis function module will be enabled.

6 Outlook

       Based on the analysis of the energy consumption operation effect of school buildings, a typical energy consumption analysis model is established and unified analysis.

♦ Establish a building energy consumption measurement system: For the publicly-used power structure, monitor to the distribution room level, and can accurately calculate the incoming and outgoing circuit. %about).

♦ Store the collected data and form a visual chart: the system collects the data and stores it in the database, the system can meet the report query and export, and the system can display the energy consumption trend in the form of histograms, etc., to give customers a better experience.

♦ Diagnosing high energy consumption points: Managers can collect data through the system, and analyze the year-on-year and quarter-on-quarter comparisons of each circuit. A one-stage analysis can find high energy consumption points.

♦ Improve management and operation mode through energy consumption analysis: For high energy consumption points, positively improve management operations, such as: notify each group to turn off lights and shut down machines during off-hours, and include them in performance evaluation; compare the power load during work The large circuit can shift peaks and reduce excessive load at the same time; the energy consumption data can reduce the company's operating costs and increase profits.

7 Conclusion

       The energy consumption system of Changshu Ruite Electric R & D Center is designed for the problem of energy consumption in schools under the background of increasing energy problems and rising energy prices. After the construction of the energy consumption management system, it will not only reduce the workload of the staff and provide work efficiency, but also the intuitive statistical analysis results can more effectively help the building managers to make correct analysis based on the energy consumption situation and to develop in the future. Making the right decisions is of great significance to promoting and driving energy conservation and achieving energy conservation and emission reduction goals.

About the Author:

Zhang Xiaoli, female, bachelor Ankerui Electric Co., Ltd., main research direction is smart grid power supply

Review editor (Wang Jing)
For more information, please visit Ankerui Electric Co., Ltd.

Scan QR code on your phone to share this page

Download and install Gongkong APP

 

Let me evaluate

Evaluation:
general
var _hmt = _hmt || []; (function() { var hm = document.createElement("script"); hm.src = "https://hm.baidu.com/hm.js?be055eb5acfdc25d3bd72279b8418725"; var s = document.getElementsByTagName("script")[0]; s.parentNode.insertBefore(hm, s); })();